Contec CMS 8000 12 inch Patient Monitor :

The monitor has very useful features that can be used for ICU clinical monitoring with adult, pediatric and neonate Patients .  Users may select different parameter configuration according to different requirements.

The monitor, power supplied by 100-240V ,50/60Hz, having 12.1'' color TFT/ LCD Display with real-time date and waveform. It can simultaneously display upto eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.

This Patient Monitor can monitor and display  ECG , HR,  SpO2, PR, RESP, NIBP and dual-channel TEMP.  It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.

 

Major Specifications of Multipara Monitor CMS 8000

  • 12.1'' Colour TFT/ LCD, multi-language interface. 
  • Parameters :  ECG, SPO2, NIBP, RESP, 2-TEMP, PR
  • Optional: 2-IBP, ETCO2, And thermal printer
  • Suitable for adult, pediatric and neonatal patient
  • With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
  • Finish all operations by keys and knobs.
  • Maximum 8-channel waveform synchronous display.
  • Bulit-in rechargeable lithium battery
  • Alarm: Yes, audible and visual alarm, alarm events review
  • 72-hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • 32 seconds full-disclosure waveform review
  • 500 NIBP measurement date can be storage and recall
  • Date and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • Heart rate variability (HRV) analysis function
  • NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
  • Drug concentration calculation and titration table functions.

Major Specifications of Multipara Monitor CMS 8000 : 

  • 12.1'' Colour TFT/ LCD, multi-language interface. 
  • Parameters :  ECG, SPO2, NIBP, RESP, 2-TEMP, PR
  • Optional: 2-IBP, ETCO2, And thermal printer
  • Suitable for adult, pediatric and neonatal patient
  • With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
  • Finish all operations by keys and knobs.
  • Maximum 8-channel waveform synchronous display.
  • Bulit-in rechargeable lithium battery
  • Alarm: Yes, audible and visual alarm, alarm events review
  • 72-hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • 32 seconds full-disclosure waveform review
  • 500 NIBP measurement date can be storage and recall
  • Date and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • Heart rate variability (HRV) analysis function
  • NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
  • Drug concentration calculation and titration table functions.

 

Parameters Specifications : 

 

Size and Weight  :  

Size Monitor  :  314 x 145 x 264 mm
Weight Monitor :   3.9 kg

Display :  

Screen /Display :   12.1 in. Color TFT, 3 LED  Resolution:  800*600

Messages : 

 

  • 8 Waveforms Maximum
  • 1 Alarm LED (Orange/Red)
  • 1 Power LED (Green)
  • 1 Battery Charge LED (Yellow)
  • 3 Sound Mode corresponding Alarm Mode

Battery : 

  • Rechargeable 3500mAh 7.4V Li battery
  • Operating time under the normal use and full charge greater than 90 minutes

ECG  :  

  • Lead Mode :   5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
  • Lead selection :   I, II, III, aVR, aVL, aVF, V,
  • Waveform :   2 ch
  • Lead mode :   3 Leads ( R, L, F or RA, LA, LL)
  • Lead selection :   I, II, III,
  • Waveform :   1 ch
  • Gain :   2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
  • Scan speed :   12.5mm/s, 25mm/s, 50mm/s

Heart Rate  :  

  • Measure and Alarm Range :  Adult 15 ~ 300 bpm  ,  Neonate/Pediatric 15 ~ 350 bpm    Accuracy ±1% or ±1bpm, which great
  • Resolution :  1 bpm
  • Sensitivity  :  > 200 uV P-P
  • Differential Input Impedance  :  > 5 MΩ


ST Segment Monitoring Range :  

  • Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting : 

  • Type  :  ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  RONT, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Alarm  :  Available
  • Review :  Available
  • Tall T-wave rejection capability :  1.2mV
  • Heart rate averaging :   The average value of the latest 6 R-R intervals which  have ignored the maximum and minimum

RESPIRATION : 

  • Method   :       Impedance between R-F(RA-LL)
  • Scan speed :   6.25mm/s, 12.5mm/s, 25mm/s
  • Resp Rate  Measuring and Alarm Range  :   Adult 0 ~ 120 rpm   ,   Neonate/Pediatric 0 ~ 150 rpm
  • Resolution  :  1 rpm
  • Accuracy  :   ±2 rpm
  • Apnea Alarm  :   10 ~ 40 s

NIBP  :

  • Method  :  Oscillometric
  • Mode  :  Manual, Auto, STAT
  • Measuring Interval in AUTO Mode  :    1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960 Min
  • Measuring Period in STAT Mode :   5 Min
  • Alarm Type :    SYS, DIA, MEAN
  • Measuring and alarm Range 
  • Adult Mode
    • SYS 40 ~ 270 mmHg
    • DIA 10 ~ 215 mmHg
    • MEAN 20 ~ 235 mmHg
  • Pediatric Mode
    • SYS 40 ~ 200 mmHg
    • DIA 10 ~ 150 mmHg
    • MEAN 20 ~ 165 mmHg
  • Neonatal Mode
    • SYS 40 ~ 135 mmHg
    • DIA 10 ~ 100 mmHg
    • MEAN 20 ~ 110 mmHg

SpO2  :  

  • Measuring Range :   0 ~ 100%
  • Alarm Range :   0 ~ 100 %
  • Resolution  :  1 %
  • Actualization interval about 1Sec.
  • Alarm Delay  :  10 Sec.
  • Sweep speed :   12.5mm/s, 25mm/s
  • Pulse Rate  Measuring and Alarm Range :   30~250bpm
  • Resolution :  1bpm
  • Accuracy  :  ±2bpm
  •  

TEMPERATURE :  

  • Channel :  2
  • Measuring and Alarm Range :   0 ~ 50 ℃
  • Resolution :   0.1℃
  • Accuracy:  ±0.1℃
  • Actualization interval about  :  1 Sec.
  • Average Time Constant :   < 10 Sec.

 

 

 