Drager Oxylog 3000 Plus Transport Ventilator
Please sign in so that we can notify you about a reply
Description for Drager Oxylog 3000 Plus
Drager Oxylog 3000 Plus Offer high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation. Oxylog 3000 plus ventilator a cutting-edge medical device designed to provide exceptional performance and advanced features, ensuring high confidence during transport and critical care scenarios. With its versatile capabilities and user-friendly interface, this drager trasport ventilator is an invaluable machine for healthcare professionals. Integrated capnography is another remarkable feature of the Drager oxolog 3000 plus ventilator. Capnography allows for the continuous monitoring of end-tidal carbon dioxide (EtCO2) levels, providing valuable information about a patient's respiratory status.
Features of Drager Oxylog 3000 Plus:
- High Confidence during Transport: The drager oxylog 3000 plus ventilator is designed to provide reliable and high-performance ventilation, ensuring confidence during transportation of critically ill patients.
- Wide Range of Ventilation Modes and AutoFlow: The drager ventilator offers a wide range of ventilation modes, allowing healthcare professionals to adapt to different patient needs. Additionally, the AutoFlow feature adjusts the flow to maintain a constant pressure, ensuring optimal ventilation.
- Integrated Capnography: The Drager oxylog 3000 is equipped with integrated capnography, which enables continuous monitoring of carbon dioxide levels in the patient's exhaled breath. This feature provides valuable information about the patient's ventilation status and helps in assessing the effectiveness of treatment.
- Ready for Pediatric Patients: This ventilator is suitable for both adult and pediatric patients, making it versatile and adaptable to a wide range of patient populations. It includes specific settings and modes tailored to meet the unique needs of pediatric patients.
- Automatic Altitude Compensation (BTPS): The Oxylog 3000 ventilator incorporates automatic altitude compensation based on Body Temperature and Pressure, allowing accurate and reliable ventilation even at different altitudes. This feature ensures consistent performance regardless of changes in atmospheric pressure.
- Intuitive User Interface: The drager oxylog 3000 plus ventilator features an intuitive user interface that simplifies operation and reduces the learning curve for healthcare professionals. The interface provides easy access to settings, alarms, and patient data, enhancing usability and efficiency.
- Advanced Data Export Functionality: This ventilator offers advanced data export functionality, allowing healthcare providers to retrieve and analyze patient data. This feature facilitates data-driven decision-making, quality improvement initiatives, and seamless integration with electronic medical record systems.
Specification of Drager Oxylog 3000 Plus Ventilator:
Product Name | Drager Oxylog 3000 Plus Ventilator |
Brand | Drager |
Model | Oxylog 3000 Plus |
Patient Age Group | Adult |
Tidal Volume | 0.05 to 2.0 L, BTPS |
Ventilation Modes | VC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAP |
Respiratory Rate | 2 to 60/min (VC-SIMV, PC-BIPAP), 5 to 60/min (VC-CMV, VC-AC), 12 to 60/min for apnoea ventilation |
Oxygen Concentration | 40 to 100 Vol.>% |
Inspiratory Pressure | PEEP +3 to +55 mbar |
PEEP/CPAP | 0 - 20 mbar |
Inspiratory Time | 0.2 - 10 second |
Inspiratory Flow | 100 L/min @ supply pressures > 350 kPa / 51 PSI; 80 L/min @ supply pressures < 350 kPa / 51 PSI; 39 L/min @ supply pressures <270 kPa / 39 PSI |
Peak Pressure | 0 to 35 mbar (relative to PEEP), slope adjustable in slow, standard, fast |
Leakage | VTe. is approx. 60% lower than VTi (not applicable in NIV) |
Incorrect Patient Hose | The ventilator detects if an incorrect patient hose type is connected |
Temperature (device) During Operation | -20 to +50°C for the basic device, +10 to +40 °C for CO₂ sensor |
Atmospheric pressure During Operation | 570 to 1200 hPa |
Relative Humidity During Operation | 5 to 95 % (no condensation) |
Electromagnetic Compatibility | In accordance with IEC/EN 60601-1-2:2007, EN 794-3 and ISO 10651-3 |
Airworthiness | In accordance with RTCA DO-160F, sections 7, 8, 16.6, 18.3.1, 17, 19.31, 20, 21, 25 |
Mechanical Strength | In accordance with MIL-STD 810F, method 514.5 |
Temperature (device) During Operation | -20 to +50°C for the basic device, +10 to +40 °C for CO₂ sensor |
Atmospheric pressure During Operation | 570 to 1200 hPa |
Relative humidity During Operation | 5 to 95 % (no condensation) |
Electromagnetic Compatibility | In accordance with IEC/EN 60601-1-2:2007, EN 794-3 and ISO 10651-3 |
Airworthiness | In accordance with RTCA DO-160F, sections 7, 8, 16.6, 18.3.1, 17, 19.31, 20, 21, 25 |
Mechanical Strength | In accordance with MIL-STD 810F, method 514.5 |
Display Unit Size | Pixels: 240 x 128, Visible area: 108 x 56 mm |
Display Technology | Electro-luminescence (EL) |
Curve Display | Airway pressure Paw curve, flow curve, CO₂ curve (optional) |
Current Consumption | 24 V ±6 VDC |
Dimensions | 29 x 18.4 x 17.5 cm |
Weight | Approximately 5.8 kg (including internal battery) |
Options | Integrated mainstream CO₂ measurement, Real-time data export via RS232, MEDIBUS protocol, AutoFlow: volume targeted - pressure-controlled ventilation |
Ventilation Time Ratio | 1:100 to 50:1 |
Trigger Sensitivity | 1 to 15 L/min |
Measured Value Display | MVe, FiO₂, RR, VTe, PEEP, Pmean, PIP, Pplat, MVesp, RRspon, etCO₂ |
CPR-Behavior | Pressure-limited, non-constant-volume ventilation during inspiration time when Pmax is reached |
Patient Hose Types | Reusable adult hose (1,5 m / 3 m), Disposable adult hose (1,5 m / 3 m), Disposable pediatric hose (1,9 m) |
Input Voltage | 24 V ±6 VDC |
AC/DC Power Pack | Input: 100 to 240 V~ / 50 to 60 Hz / 0.9 to 0.4 A~ |
DC/DC Converter | Input: 12 / 24 / 28 VDC; 5 A / 2.5 A / 2.1 A |
Operating Time | Approximately 9.5 hours |
Operation Time | Approximately 7.5 hours |
Battery Type | Lithium-ion battery |
Charging Time | Approximately 4 hours |
Specification and main features of Drager Oxylog 3000 Plus
Estimated Delivery
5-10Days
Warranty
- From Manufacurer ,
- 1 Years
Brand/Manufacturer
Brand
Drager Medical
Product Specifications
Product Name
Drager Oxylog 3000 Plus Transport Ventilator
Product Model
Oxylog 3000 Plus
Qty./BOX
1
Key Technical Specification
Tidal Volume
- 50-2000 mL
Ventilator Mode
- VC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAP
Patient Category
- Adult
Ventilation Type
- Volume Controlled
Weight & Dimensions
Product Dimension (mm)
290 x 184 x 175
Product Weight
5.8Kg
Power Supply & Battery
AC input voltage
100-240 V
Battery Backup
7.5Hr.
Battery type
Lithium Battery
BATTERY CHARGING PERIOD
4