Philips Goldway GS20 Cardiac Patient Monitor

HS06340
115,000.00
140,000.00
You save: 25,000.00
In stock
Price in points: 1150000 points
+
Request For Quote

We accept COD Payment on this product

Pay Booking Amount Now : 10,000.00

Pay Balance on COD : 105,000.00 + Shipping

Check availability at your Pincode

Add to wish list
Our advantages
  • — GST Invoice available
  • — Mail /SMS notification
  • — Easy Return and exchange
  • — Multiple payment options
  • — Best price
Delivery
Shipping time and rates:
Delhi
Payment options
  • - Credit/Debit Card Payment
  • - Netbanking and UPI Payment
  • - Easy EMI on selected products
  • - NEFT or RTGS to Bank Account
Country of Origin (COO)USA Product ConditionNew Estimated Delivery5-7 Days Installation Not Required Warranty 1 Year, From manufacturer BrandPhilips ColorWhite
Description for Philips GS20 Patient Monitor
The Philips Goldway GS20 is a top-of-the-line patient monitor that provides accurate details and actionable patient data during patient monitoring. With its 10-inch display, the Philips gs20 patient monitor is easy to use and provides clinicians with all the information they need to make informed decisions about their patients' care. The Philips GS20 patient monitor offers essential measurements for daily use, such as the oxyCRG and Mini-trend software functions that provide basic clinical support. It can be connected to the Philips Efficia CMS200 Central Station, and includes an HL7 data output function for EMR/HIS integration. Moreover, the monitor features the Philips FAST SpO2 and Philips ECG algorithms.

Features of Philips Goldway GS20

1.) Advanced functionalities
Philips GS20 patient monitor provides real-time data on cardiac and respiratory conditions in order to fit different clinical settings. As well as specific monitoring parameters such as Philips ST / AR 3-and5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO2/PR, ST and arrhythmia monitoring, it also offers options for 2-channel intrusive blood pressure and Microstream etCO2 monitoring.
2.) Ease of use
GS20 patient monitor has a 10.4-inch color display with flexible display modes such as large number display, minitrend, OxyCRG, and the height adjustment function of the auto waveform channel to fit different clinical settings. For maximum ease of use, intuitive menus, fixed key access, bright color screen, and optional touchscreen have all been designed.
3.) Compact and cost-effective
The Philips goldway gs20 patient monitor, designed in compliance with Philips exacting quality standards, offers market-proven critical parameters in a lightweight, cost-effective display to produce precise measurement results on your tight budget. 
4.) Works with Efficia consumables
The Philips gs20 patient monitor is designed to be compatible with consumables from Philips Efficia, which are also used on patient monitors from the Philips Efficia CM series, to reduce your total cost of ownership by sharing consumables from Philips across various care settings.

Specification of Philips Goldway G20

ECG  
Lead type 3-lead or 5-lead selectable
Lead selection, 3-lead I, II, III
Lead selection, 5-lead I, II, III, aVR, aVL, aVF, V
HR measurement Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm
HR accuracy ±5 bpm or ±1 %, whichever is greater
Arrhythmia 21 calls
ST measurement range -2.5 mV – +2.5 mV
Waveform speed 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
Gain selection x 1/4, x 1/2, x 1, x 2, x 4, Auto
Pacemaker detection Yes
Protection Against electrosurgical interference and defibrillation
Non-invasive blood pressure (NBP)  
Method Automatic oscillometric
Parameters SYS/DIA/MAP/Pulse Rate
Operating mode Manual/Auto/STAT
Auto measure intervals 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Units mmHg/kPa
Cuff pressure range, adult / pediatric 0 – 300 mmHg ( 0 kPa – 40.0 kPa)
Cuff pressure range, neonate 0 – 150 mmHg ( 0 kPa – 20.0 kPa)
Systolic measurement range, adult/ pediatric 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa)
Systolic measurement range, neonate 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa)
Diastolic measurement range, adult / pediatric 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa)
Diastolic measurement range, neonate 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa)
MAP measurement range, adult / pediatric 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
MAP measurement range, neonate 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
Accuracy, maximum standard deviation 8 mmHg (1.1 kPa)
Accuracy, mean error ±5 mmHg (±0.7 kPa)
Pulse rate range 40 bpm – 240 bpm
Pulse rate accuracy ±5bpm or ±5%, whichever is greater
SpO2 (Philips SpO2 technology)  
Measurement range 0 – 100 %
Accuracy 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified
Waveform speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Pulse rate range 30 bpm – 300 bpm
Pulse rate accuracy ±2 bpm or ±2%, whichever is greater
Perfusion index Yes
Respiration (RESP)  
Measurement method Thoracic impedance
Measurement range 0 rpm – 150 rpm
Accuracy 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
Waveform speed 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
Gain selection x 1/2, x 1, x 2
Apnea alarm Yes, 10 – 60 s
Work mode Auto or manual (threshold)
RESP lead RA-LL
Temperature (TEMP, 2-channel)  
Measurement range 0 – 50℃ (32℉ – 122℉)
Resolution 0.1℃ (0.2℉)
Accuracy ±0.1℃ (±0.2℉) (without sensor)
Units ℃ / ℉
Minimum measuring time Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes
Capnopgraphy (etCO2, optional)  
Method Microstream, infrared absorption (Oridion)
Parameters awRR, etCO₂, inCO₂
Measurement range 0 – 99 mmHg (0 kPa – 13.2 kPa)
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) ±2 mmHg (±0.28 kPa)
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
awRR range 0-150 rpm
awRR accuracy, 3 rpm – 70 rpm ±1 rpm
awRR accuracy, 71 rpm – 120 rpm ±2 rpm
awRR accuracy, 121 rpm – 150 rpm ±3 rpm
Invasive Blood Pressure  
Accuracy ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
Invasive blood pressure (IBP, 2-channel, optional)
Parameters SYS/DIA/MAP/Pulse Rate
Measurement range -50 – 400 mmHg (-6.6 kPa – 53.3 kPa)
Waveform speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Resolution 1 mmHg (0.13 kPa)
Units mmHg/kPa/cmH₂O
Transducer sensitivity 5 uV/V/mmHg
Pulse rate range 30 bpm – 254 bpm
Pulse rate accuracy ±2bpm or ±2%, whichever is greater
Sampling rate 62.5 samples per second
Recorder (optional)  
Type Built-in thermal recorder, 3 channels
Print mode Real-time recording, timed recording, alarm-activated recording
Print speed Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Display  
Type Color TFT LCD, 4:3
Size 10.4+611:631″
Resolution 800 x 600 pixels
Channels Max 11 channels (auto waveform channel height adjustment)
Power supply  
AC power input 100 – 240 VAC, 50/60 Hz
Battery Rechargeable Li-Ion battery Maximum 2.5-hour continuous monitoring (1 battery)
Weight and dimensions  
Net weight Approx. 3.5 kg without battery
Dimensions (w x d x h) 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
Safety approval and quality system  
Safety standard IEC 60601-1-2:2014
Electromagnetic environment IEC 60601-1-2:2000/A1:2014
Quality system ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
Waterproof IPX1
Data review and storage  
Data review and storage 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events
External interface (standard)  
External interface ECG analog output VGA output Nurse call LAN USB
Cardiac Output (optional)  
Measurement method Right heart thermodilution
Measurement range 0.1 l/min – 20.0 l/min
Measurement accuracy ±0.2 l/min or ±10 %, whichever is greater
Blood temperature range 27℃ – 43℃ (80.6℉ – 109.4℉)
Blood temperature accuracy ± 0.1℃
Injection temperature 0℃ – 27℃ (32℉ – 80.6℉)

List of Supply with Goldway Philips Monitor:

Name of accessoriesQuantity
ECG Cable 1
SpO2 Sensor1
NIBP Cuff (Adult) with cable1
Power Cable1
User Manual1
Philips Goldway GS20 | Multiparamonitor | Features ,specification and operation of Patient monitor
Specification and main features of Philips GS20 Patient Monitor
Estimated Delivery
5-7Days
Warranty
  • 1 Year ,
  • From manufacturer
Brand/Manufacturer
Brand
Philips
Product Specifications
Color
White
Product Name
Philips Goldway GS20 Patient Monitor
Product Model
GS20
Qty./BOX
1
Weight & Dimensions
Product Dimension (mm)
316 mm x 265 mm x 131
Product Weight
3.5Kg
Display and User Interface
Screen Size (Diagonal)
  • 10.4 Inch
Display Type
TFT Display
Power Supply & Battery
AC input voltage
100-240 V
Battery Backup
3Hr.
Battery type
Li-ion Battery
Technical Specifications
Arrhythmia Detection
Yes
Find similar
Reviews for Philips GS20 Patient Monitor from buyers

No reviews found

Possibly you may be interested
  • Most Popular
  • Bestsellers
  • Recently Viewed
 
 
 
Products Compared Frequently
User Interface
-
-
Knob
-
Essential Parameters
Country of Origin (COO)
USA
China
-
-
Product Condition
New
New
New
New
Estimated Delivery
5-7Days
5 - 10Days
5 - 10Days
5-10Days
Installation
Not Required
Not Required
Not Required
Not Required
Warranty
1 Year, From manufacturer
1 Year, From manufacturer
1 Year, From manufacturer
1 Years
Brand/Manufacturer
Google Export
Condition
new
-
-
-
Product Specifications
Color
White
-
-
-
Product Name
Philips Goldway GS20 Patient Monitor
Comen C50 Cardiac patient monitor
Technocare 9009B Cardiac Monitor
BPL Elite View EV100 Touch Multipara Monitor
Product Model
GS20
C50
9009B
EV100
Qty./BOX
1
1
1
1
Machine Operation
-
-
-
Touch Screen
Weight & Dimensions
Product Dimension (mm)
316 mm x 265 mm x 131
-
-
-
Product Weight
3.5Kg
-
-
2.8Kg
Display and User Interface
Screen Size (Diagonal)
10.4Inch
10.4Inch
12.1Inch
12Inch
Display Type
TFT Display
TFT Display
-
-
Power Supply & Battery
AC input voltage
100-240 V
100 - 240 V
100 - 240 V
-
Battery Backup
3Hr.
4Hr.
2Hr.
2Hr.
Battery type
Li-ion Battery
Li-ion Battery
-
Lithium-ion
Battery capacity
-
4000mAh
-
2600mAh
Technical Specifications
Arrhythmia Detection
Arrhythmia Detection
Arrhythmia Detection
Arrhythmia Detection
Arrhythmia Detection
Standard Parameters
-
ECG/HR, SpO2, PR, NIBP, RESP, Dual TEMP, PR
ECG, Respiration, Pulse Rate, SPO2 , NIBP, Temperature
12 Lead ECG, RESP, SP02 (MASIMO / Nellcor / Digital), NIBP and TEMP.
Optional Parameters of Patient Monitor
-
Dual IBP, Etco2, Cardiac Output, Recorder
-
IBP, ETCO2, AGM, CO, ICG.
ECG Waveform
-
-
5
-
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 5 days

Easy return and exchange on products*